ad9361_adc HDL Worker
Detail
The ad9361_adc_sub.hdl subdevice worker supports the ad9361_adc.hdl device worker. The ad9361_adc_sub.hdl subdevice sends a data bus containing 24-bit parallel I/Q data in the AD9361’s DATA_CLK_P pin clock domain via the dev_adc dev signal port. Either of data streams from the two AD9361 RX channels may be sent to an instance of ad9361_adc.hdl. Which RX channel data stream is sent is determined within the ad9361_adc_sub.hdl subdevice worker. The Q0.15 I/Q values on the ad9361_adc.hdl output port are sign extended from the AD9361’s 12-bit I/Q ADC bus. For more information see Ad9361 adc sub (ad9361_adc_sub).
The ad9361_adc.hdl worker passes data from the dev_adc dev signal bus through an asynchronous First-In-First-Out (FIFO) buffer to achieve clock domain crossing. The FIFO’s output side is in the HDL container’s control clock domain. Note that the HDL container’s control clock rate is platform-specific. The FIFO’s depth in number of samples is determined at build-time by the fifo_depth parameter property. An overrun property indicates when samples have been dropped due to the FIFO being full, which is possible when backpressure overcomes the ADC sample rate for long enough to fill up the FIFO. The output data port generates messages whose length in bytes is determined at runtime by the messageSize property.
Control Timing and Signals
The ad9361_adc.hdl device worker contains two clock domains: the clock from the Control Plane, and the adc_clk clock from the dev signal.
The latency from the dev signal data bus to the output port is non-deterministic due to data flowing through an asynchronous FIFO with each side in a different clock domain. This non-determinism exists even in the absense of backpressure. In the presence of backpressure, the latency increases in an amount directly proportional to the degree to which the FIFO is full.
Performance and Resource Utilization
The FPGA resource utilization and Fmax are included for this worker. Fmax refers to the maximum allowable clock rate for any registered signal paths within a given clock domain for an FPGA design. Fmax in the table below is specific only to this worker and represents the maximum possible Fmax for any OpenCPI bitstream built with this worker included. Note that the Fmax value for a given clock domain for the final bitstream is often worse than the Fmax specific to this worker, even if this worker is the only one included in the bitstream. Note also that the DATA CLK P devsignal’s rate will only ever go as high as 245.76 MHz as shown in the reference manual.
Configuration |
OCPI Target |
Tool |
Version |
Device |
Registers (Typ) |
LUTs (Typ) |
Fmax (MHz) (Typ) control plane clock |
Fmax (MHz) (Typ) dev_adc.adc_clk clock |
Memory/Special Functions |
0 |
zynq |
Vivado |
2017.1 |
xc7z020clg484-1 |
188 |
133 |
202 |
339 |
RAMB18: 1 |
0 |
stratix4 |
Quartus |
17.1.0 |
EP4SGX230KF40C2 |
187 |
185 |
N/A |
N/A |
N/A |
0 |
virtex6 |
ISE |
14.7 |
6vlx240tff1156-1 |
208 |
258 |
335.373 |
369 |
RAM64M: 8 |
Worker Properties
fifo_depthType:
ulongAccess:
Parameter:
TrueWritable:
FalseInitial:
FalseVolatile:
FalseRead back:
False
Default value:
None
ocpi_buffer_size_OUTType:
ushortAccess:
Parameter:
FalseWritable:
FalseInitial:
TrueVolatile:
FalseRead back:
False
Default value:
0
ocpi_blocked_OUTType:
ulongAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
ocpi_max_latency_OUTType:
ushortAccess:
Parameter:
TrueWritable:
FalseInitial:
FalseVolatile:
FalseRead back:
False
Default value:
None
ocpi_latency_OUTType:
ushortAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
ocpi_messages_OUTType:
ulongAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
ocpi_bytes_OUTType:
ulongAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
Worker Ports
OUTProtocol:
iqstreamOptional:
True
dev_adcType:
devsignal
Outputs:
Interfaces (other than data I/O ports):
Worker Signals
presentDirection:
outDifferential:
falsePin:
false
adc_data_IDirection:
inWidth:
12Differential:
falsePin:
false
adc_data_QDirection:
inWidth:
12Differential:
falsePin:
false
adc_clkDirection:
inDifferential:
falsePin:
false
adc_giveDirection:
inDifferential:
falsePin:
false
Utilization