The response time and output level of the circuit are programmable, as is the ability to update/hold the gain differential used in the feedback loop. The size of the averaging window used for peak detection is build-time programmable using the AVG_WINDOW_p parameter, which is recommended to be a power-of-two to enable hardware division implementation with shift registers.
The ref property controls the desired output amplitude, while the mu property controls the AGC time constant, thus determining the response time of the circuit.
This implementation uses three multipliers to process input data at the clock rate - i.e. this worker can handle a new input value every clock cycle. This circuit will produce output one clock cycle after each valid input, but the input-to-output latency is actually three valid clock cycles.
The AGC Real worker utilizes the OCPI iqstream_protocol for both input and output ports. The iqstream_protocol defines an interface of 16-bit real signed samples. The DATA_WIDTH_p parameter may be used to reduce the worker’s internal data width to less than 16-bits.
The AGC Real worker uses the clock from the Control Plane and standard Control Plane signals.
Worker Properties
DATA_WIDTH_pType:
ushortAccess:
Parameter:
TrueWritable:
FalseInitial:
FalseVolatile:
FalseRead back:
False
Default value:
None
AVG_WINDOW_pType:
ushortAccess:
Parameter:
TrueWritable:
FalseInitial:
FalseVolatile:
FalseRead back:
False
Default value:
None
holdType:
boolAccess:
Parameter:
FalseWritable:
TrueInitial:
FalseVolatile:
FalseRead back:
False
Default value:
false
refType:
ushortAccess:
Parameter:
FalseWritable:
TrueInitial:
FalseVolatile:
FalseRead back:
False
Default value:
16383
muType:
ushortAccess:
Parameter:
FalseWritable:
TrueInitial:
FalseVolatile:
FalseRead back:
False
Default value:
None
ocpi_buffer_size_outType:
ushortAccess:
Parameter:
FalseWritable:
FalseInitial:
TrueVolatile:
FalseRead back:
False
Default value:
0
ocpi_blocked_outType:
ulongAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
ocpi_max_latency_outType:
ushortAccess:
Parameter:
TrueWritable:
FalseInitial:
FalseVolatile:
FalseRead back:
False
Default value:
None
ocpi_latency_outType:
ushortAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
ocpi_messages_outType:
ulongAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
ocpi_bytes_outType:
ulongAccess:
Parameter:
FalseWritable:
FalseInitial:
FalseVolatile:
TrueRead back:
False
Default value:
None
Worker Ports
inProtocol:
rstreamOptional:
False
outProtocol:
rstreamOptional:
False
Inputs:
Outputs:
Utilization
Utilization reporting is not currently implemented.