e31x_mimo_xcvr_ad5662 HDL Worker

Detail

The e31x_mimo_xcvr_ad5662 device worker is used to configure the e31x_mimo_xcvr_ad5662 MicroDAC hardware block. The hardware takes in a digital word and converts it to an analog voltage value based on the number written. The protocol used to write the DAC value to hardware is compatible with SPI. The e31x_mimo_xcvr_ad5662 worker will write the DAC value over SPI to the hardware on property write.

The e31x_mimo_xcvr_ad5662 device worker uses the standard Control Plane signals and the raw property interface.

Worker Properties

  • voltageScale

    • Type: ulong

    • Access:

      • Parameter: False

      • Writable: True

      • Initial: False

      • Volatile: False

      • Read back: False

    • Default value: 32767

Worker Signals

  • TUNE_DAC_SYNCn

    • Direction: out

    • Differential: false

    • Pin: false

  • TUNE_DAC_SCLK

    • Direction: out

    • Differential: false

    • Pin: false

  • TUNE_DAC_SDIN

    • Direction: out

    • Differential: false

    • Pin: false

  • VCTCXO_TO_MB

    • Direction: in

    • Differential: false

    • Pin: false

Utilization

Utilization reporting is not currently implemented.